If you are going to seal an exterior slab find a sealer that transmits water vapor breathes.
Vapor barrier above concrete slab.
We find ourselves having to explain that the vapor retarder wasn t required or necessary for a concrete garage floor poured at or above grade.
It is also possible that too much water or cement paste would be absorbed from the concrete by the sand but probably not under most circumstances.
Choosing a vapor barrier.
If it doesn t a moisture imbalance could eventually cause a flooring failure.
One laboratory drying study indicated that 4 in.
The 2012 international residential code states.
Cure with waterproof sheets rather than with water or curing compounds.
The rate that moisture escapes from a slab depends on the concrete w c the density of the finish the ambient conditions above the slab and the moisture below the slab.
These 10 mil and 15 mil vapor barriers are very puncture resistant and will not break down over time creating a true moisture barrier between the sub grade and.
This guide says in section 2 4 1.
Concrete garage floors vapor transmission.
In general place the concrete slab directly on top of the vapor barrier with the subbase below.
Some builders prefer to place the vapor barrier below the insulation or even below the gravel bed because they find.
For a vapor barrier below a concrete floor slab most choose 6 to 10 mil polyethylene.
Aci 302 1r 11 guide for concrete floor and slab construction doesn t advocate universal use of vapor barriers but does make recommendations for their proper use.
Our moistureblock is a 6 mil polyethylene film vapor barrier that is used during the installation process with floating laminate luxury vinyl planks and engineered wood floors.
If you want to make sure your slab on ground gets dry and stays dry use a vapor barrier.
However the vapor barrier under the slab must have a lower degree of permeance than the flooring or floor covering above the slab.
Vapor barriers come in two types 6 mil vapor barrier roll.
Thick concrete samples having a w c 0 50 and sealed from below required 82 days for the vapor emission rate to reach 3 0.
Most exterior slabs do not need a vapor barrier.
But consider going with a barrier that has water vapor permeance less than 0 3 perms.
Is a vapor retarder barrier necessary for under the concrete slab of a garage or basement.
Because extruded polystyrene insulating board will absorb little moisture the vapor barrier can be placed above or below the slab insulation.